What should do before operating billet induction heating furnace ?

What should do before operating billet induction heating furnace ? 

You may know very clear about your billet size, capacity and heating process, but do you know what should do before operating billet induction heating furnace ? Correct checking for the billet induction heating furnace will avoid some failure and damage. 

Exterior Checking  for the billet induction heating furnace

① Checking all the components to ensure they are in good condition

② Checking all the fixtures to ensure they are in good condition

③ Checking all the wiring connections and the welding points are good,

④ Ensure all the connections are correct.

⑤ Checking the insulation between main circuit, control circuit and cabinet cover,all phases  with the  multimeter.

Water System Checking

Opening the input water valve and adjust the hydraulic pressure to 0.1-0.15Mpa then check water way has leakage or not.

Power checking

① When the air switch of the two low-voltage distribution close separately, the corresponding main power lamp will be on.

② When closing the control power, the corresponding indicator lamp will be on.

③ Checking the LED indicator lamp of inverter trigger pulse is on slightly or not.

Any more information about Forever medium frequency heating equipment , please send us inquiry.